This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
2017:groups:tools:contur_for_light_scalar_particles [2017/10/01 11:27] jonathan.butterworth |
2017:groups:tools:contur_for_light_scalar_particles [2017/10/11 23:47] (current) jonathan.butterworth |
||
---|---|---|---|
Line 49: | Line 49: | ||
{{:2017:groups:tools:cl_78wzg_nso.png?200|}} (l+l−) or (l+EmissT)+γ | {{:2017:groups:tools:cl_78wzg_nso.png?200|}} (l+l−) or (l+EmissT)+γ | ||
- | {{:2017:groups:tools:cl_8metg_nso.png?200|}} EmissT+γ | + | {{:2017:groups:tools:cl_8metg_nso.png?200|}} $E_T^{\rm miss} + \gamma (\gamma)$ |
{{:2017:groups:tools:cl_78photons_nso.png?200|}} Inclusive and di-photons | {{:2017:groups:tools:cl_78photons_nso.png?200|}} Inclusive and di-photons | ||
Line 64: | Line 64: | ||
== Mϕ=80 GeV, Λ=7.5 TeV == | == Mϕ=80 GeV, Λ=7.5 TeV == | ||
- | > [[http://www.hep.ucl.ac.uk/~jmb/Work/LH/NSCPO/8TeV/mP_80_f0_7500/contur-plots/|Page of plots]]: This point is chosen to look at the higher end of the Mϕ range, where the sensitivity is greater, and so we look at a high Λ value. Again the sensitivity is driven by [[http://www.hep.ucl.ac.uk/~jmb/Work/LH/NSCPO/8TeV/mP_80_f0_7500/contur-plots/ATLAS_2016_I1448301_NU/index.html|this paper]], but now it is the γγ+EmissT cross section that does the work. | + | > [[http://www.hep.ucl.ac.uk/~jmb/Work/LH/NSCPO/8TeV/mP_80_f0_7500/contur-plots/|Page of plots]]: This point is chosen to look at the higher end of the Mϕ range, where the sensitivity is greater, and so we look at a high Λ value. Again the sensitivity is driven by [[http://www.hep.ucl.ac.uk/~jmb/Work/LH/NSCPO/8TeV/mP_80_f0_7500/contur-plots/ATLAS_2016_I1448301_NU/index.html|this paper]], but now it is the γγ+EmissT cross section that does the work. And again once the 7 TeV data are included, the inclusive and diphotons cover this point on their own. |
== CP-even results== | == CP-even results== | ||
Line 79: | Line 79: | ||
Note that the sensitivity at low Mϕ and Λ is somewhat reduced, especially for the EmissT+γ channel. Presumably something to do with the angular distributions of the decay photons of the ϕ, but to be studied... | Note that the sensitivity at low Mϕ and Λ is somewhat reduced, especially for the EmissT+γ channel. Presumably something to do with the angular distributions of the decay photons of the ϕ, but to be studied... | ||
+ | |||
+ | There is still 95% exclusion even at the highest Λ values studied. Would be interesting to see how far it goes. Update - not very far? Here's an 8 TeV run going to higher values. | ||
+ | |||
+ | {{:2017:groups:tools:cl_8extended.png?300|}}{{:2017:groups:tools:contur_8tev-cpe-extended.png?300|}} | ||